본문 바로가기 주메뉴 바로가기

인류의 건강과 생명공학 발전을 위해 봉사하는 기업 드림셀

We Serving the Health and Biotechnology of Humanity

제품정보

> 제품정보 > 시약 > 국내 공식 대리점 > Lumit™ TNF-α (Human) Immunoassay, 100 assays
제품명

Lumit™ TNF-α (Human) Immunoassay, 100 assays

제품코드 : W6050

제품정보 : Inflammation Assay

  • Lumit Immunoassay는 washing, transfer, sample dilution 단계없이 세포 배양 상태에서 바로 analyte를 특정할 수 있는 새로운 immunoassay입니다.
  • [W6050] 100 assays, [W6052] 500 assays, [W6051] 1,000 assays

제품문의

  • 전화번호
    2292-8870

제품상세

No-Wash Immunoassay for TNF-α Detection

  • Fast add-and-read protocol performed directly on cells
  • Luminescent detection with just a plate-reading luminometer
  • Scalable to 96- or 384-well plates

Quantify Cytokine Release Without Tedious Wash Steps

The Lumit™ TNF-α Immunoassay quantitatively measures released TNF-α in cell culture samples using a simple, no-wash protocol. Just add labeled antibodies to the sample, add detection reagent and read luminescent signal using a standard plate-reading luminometer. The entire protocol is completed in less than 70 minutes! The assay can be used directly on cells in culture or culture medium transferred to a separate assay plate.

How the Lumit™ TNF-α Immunoassay Works

Primary antibodies to TNF-α were selected for their specific and sensitive detection and labeled with the LgBiT and SmBiT subunits of NanoBiT® Luciferase. In the presence of TNF-α, the subunits are brought together to form an active luciferase enzyme. Addition of optimized substrate generates a bright luminescent signal proportional to TNF-α levels.

How the Lumit™ IL-2 Immunoassay Works

Simple One-Plate Protocol, No Wash Steps

Lumit™ IL-2 Immunoassay Workflow

Large Dynamic Range of Lumit™ TNF-α Detection

The pg/ml to ng/ml linear range of Lumit™ detection covers expected concentrations for most cell models.

lumit tnf-alpha standard curve 17850ma

Assay

TNF-α Human Immunoassay

Limit of Detection (LOD)

2.9pg/ml (3 SD above background)

Dynamic Range

18.2pg/ml – 25ng/ml

Minimal Detectable Dose (MDD)

2.0pg/ml (2 SD above background)

Assay Time

70 minutes

Sample Type

Cell culture supernatants

SD=Standard Deviation

Sensitive Detection of TNF-α Without Sample Dilution

Data showing sensitive detection of TNF-α without sample dilution

When treated with a Cell Stimulation Cocktail (CSC), human PBMCs release TNF-α. After treatment for 24, 48 or 72 hours, Lumit™ TNF-α Human Immunoassay reagents were added directly to cell wells to measure TNF-α release. No sample dilution was required to measure quantities of TNF- α release.

Multiple Cytokine Detection by Split-Sample Analysis

Split-sample analysis for detection of IL-2, IL-6, IFN-γ and TNF-α using corresponding Lumit™ Cytokine Immunoassay.18001ma

Human PBMCs were plated in a 96-well plate in 100µl and treated for 24 hours with cell stimulation cocktail (CSC), lipopolysaccharide (LPS) or R848. Four 20μl aliquots were transferred to a 384-well plate for detection of IL-2, IL-6, IFN-γ and TNF-α with the corresponding Lumit™ Cytokine Immunoassay. This simple approach for profiling cytokine 

아래 링크를 클릭하시면 제품에 대한 자세한 정보를 확인하실 수 있습니다.