| Description | This Mouse IL2 ELISA Kit was designed for the quantitative measurement of Mouse IL2 protein in serum, plasma, tissue homogenates, cell culture supernates. It is a Sandwich ELISA kit, its detection range is 15.6 pg/mL-1000 pg/mL and the sensitivity is 3.9 pg/mL. |
| Alternative Names | Il2 ELISA kit; Il-2Interleukin-2 ELISA kit; IL-2 ELISA kit; T-cell growth factor ELISA kit; TCGF ELISA kit |
| Abbreviation | IL2 |
| Uniprot No. | P04351 |
| Species | Mus musculus (Mouse) |
| Sample Types | serum, plasma, tissue homogenates |
| Detection Range | 31.25 pg/ml - 2000 pg/ml |
| Sensitivity | 7.8 pg/ml |
| Assay Time | 1-5h |
| Sample Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Immunology
|
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Materials provided | - A micro ELISA plate ---The 96-well plate has been pre-coated with an anti-mouse IL-2 antibody. This dismountable microplate can be divided into 12 x 8 strip plates.
- Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve.
- One vial Biotin-labeled IL-2 antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody.
- One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic.
- One vial Biotin-antibody Diluent (15 ml/bottle) ---Dilute the Biotin-antibody.
- One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution.
- One vial Sample Diluent (50 ml/bottle)---Dilute the sample to an appropriate concentration.
- One vial Wash Buffer (25 x concentrate) (20 ml/bottle) ---Wash away unbound or free substances.
- One vial TMB Substrate (10 ml/bottle) ---Act as the chromogenic agent. TMB interacts with HRP, eliciting the solution turns blue.
- One vial Stop Solution (10 ml/bottle) ---Stop the color reaction. The solution color immediately turns from blue to yellow.
- Four Adhesive Strips (For 96 wells) --- Cover the microplate when incubation.
- An instruction manual
|
| Materials not provided | - A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
- An incubator can provide stable incubation conditions up to 37°C±5°C.
- Centrifuge
- Vortex
- Squirt bottle, manifold dispenser, or automated microplate washer
- Absorbent paper for blotting the microtiter plate
- 50-300ul multi-channel micropipette
- Pipette tips
- Single-channel micropipette with different ranges
- 100ml and 500ml graduated cylinders
- Deionized or distilled water
- Timer
- Test tubes for dilution
|
| ELISA Data Analysis | Watch ELISA data processing video & download Curve Expert if needed |
Troubleshooting and FAQs | ELISA kit FAQs |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Lead Time | 3-5 working days |