본문 바로가기 주메뉴 바로가기

인류의 건강과 생명공학 발전을 위해 봉사하는 기업 드림셀

We Serving the Health and Biotechnology of Humanity

제품정보

> 제품정보 > 시약 > 해외 공식 대리점 > [CEC907Hu] ELISA Kit for Fibroblast Growth Factor 18 (FGF18)
제품명

[CEC907Hu] ELISA Kit for Fibroblast Growth Factor 18 (FGF18)

제품코드 : CEC907Hu

제품정보 : Cytokine;

  • Organism Species: Homo sapiens (Human)
  • Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
  • Test Method: Competitive Inhibition
  • Assay Length: 2h
  • Detection Range: 31.2-500pg/mL
  • Sensitivity: The minimum detectable dose of this kit is typically less than 13.9pg/mL

제품문의

  • 전화번호
    2292-8870

제품상세

Specificity

This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 18 (FGF18).
No significant cross-reactivity or interference between Fibroblast Growth Factor 18 (FGF18) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Fibroblast Growth Factor 18 (FGF18) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibroblast Growth Factor 18 (FGF18) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)98-105102
EDTA plasma(n=5)96-104101
heparin plasma(n=5)96-104101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibroblast Growth Factor 18 (FGF18) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)79-101%95-103%97-104%90-97%
EDTA plasma(n=5)84-91%97-105%82-101%92-101%
heparin plasma(n=5)91-104%86-96%84-103%91-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1Assay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
Reagent Diluent1×300µLStop Solution1×6mL
TMB Substrate1×9mLInstruction manual1
Wash Buffer (30 × concentrate)1×20mL

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.