본문 바로가기 주메뉴 바로가기

인류의 건강과 생명공학 발전을 위해 봉사하는 기업 드림셀

We Serving the Health and Biotechnology of Humanity

제품정보

> 제품정보 > 시약 > 해외 공식 대리점 > [MEA049Ra] Mini Samples ELISA Kit for Interferon Gamma (IFNg)
제품명

[MEA049Ra] Mini Samples ELISA Kit for Interferon Gamma (IFNg)

제품코드 : MEA049Ra

제품정보 : Cytokine;Infection immunity;

  • Organism Species: Rattus norvegicus (Rat)
  • Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
  • Test Method: Double-antibody Sandwich
  • Assay Length: 3h
  • Detection Range: 15.6-1,000pg/mL
  • Sensitivity: The minimum detectable dose of this kit is typically less than 6.0pg/mL

제품문의

  • 전화번호
    2292-8870

제품상세

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Interferon Gamma (IFNg).
No significant cross-reactivity or interference between Mini Samples Interferon Gamma (IFNg) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mini Samples Interferon Gamma (IFNg) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Interferon Gamma (IFNg) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)82-9186
EDTA plasma(n=5)86-10191
heparin plasma(n=5)80-9086

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Interferon Gamma (IFNg) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Interferon Gamma (IFNg) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Interferon Gamma (IFNg) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)92-105%97-104%80-104%97-105%
EDTA plasma(n=5)79-90%88-102%98-105%93-104%
heparin plasma(n=5)79-91%81-90%95-102%96-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×60µLAssay Diluent A1×6mL
Detection Reagent B1×60µLAssay Diluent B1×6mL
TMB Substrate1×4.5mLStop Solution1×3mL
Wash Buffer (30 × concentrate)1×10mLInstruction manual1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.