본문 바로가기 주메뉴 바로가기

인류의 건강과 생명공학 발전을 위해 봉사하는 기업 드림셀

We Serving the Health and Biotechnology of Humanity

제품정보

> 제품정보 > 시약 > 국내 공식 대리점 > Lumit™ HMGB1 (Human/Mouse) Immunoassay, 100 assays
제품명

Lumit™ HMGB1 (Human/Mouse) Immunoassay, 100 assays

제품코드 : W6110

제품정보 : Inflammation Assay

  • Lumit Immunoassay는 washing, transfer, sample dilution 단계없이 세포 배양 상태에서 바로 analyte를 특정할 수 있는 새로운 immunoassay입니다.
  • [W6110] 100 assays, [W6112] 500 assays

제품문의

  • 전화번호
    2292-8870

제품상세

Fast, No-Wash Detection of HMGB1

High-Mobility Group Box 1 (HMGB1) functions as a damage-associated molecular pattern (DAMP) released from cells in inflammatory responses. HMGB1 is often measured as a key biomarker of immunogenic cell death, a specialized form of cell death that results in an immune response. HMGB1 also functions as a proinflammatory cytokine. Current methods to detect HMGB1, such as ELISA, require tedious wash steps and lengthy protocols. Lumit™ technology simplifies HMGB1 quantitation with an add-mix-measure protocol completed in 90 minutes or less.

How the Lumit™ HMGB1 Immunoassay Works

Primary antibodies to HMGB1, selected for their specific and sensitive detection, are labeled with the LgBiT and SmBiT subunits of NanoBiT® Luciferase. In the presence of HMGB1, the subunits are brought together to form an active luciferase enzyme. Addition of optimized substrate generates a bright luminescence signal proportional to HMGB1 levels. The assay detects both human and mouse HMGB1.

How the lumit HMGB1 assay works.

Simple One-Plate Protocol, No Wash Steps

lumit HMGB1 immunoassy workflow

Large Dynamic Range of HMGB1 Detection

Due to the homology of human and mouse HMGB1, the kit can be used for both species with minimal performance differences.

Lumit™ HMGB1 Human Immunoassay standard curve.
Lumit™ HMGB1 Mouse Immunoassay standard curve.

Target

Human HMGB1

Mouse HMGB1

Limit of Detection 
(3SD above background)

1ng/ml 

3ng/ml 

Dynamic Range

4–1,000ng/ml

3–2,187ng/ml

Assay Time

90 minutes

Sample Type

Cell culture samples

SD=Standard Deviation

Dual DAMP Measurements in a Human Cell Line

Data showing ATP release and HMGB1 release after mitoxantrone treatment

In parallel assay plates, U937 cells were dosed with mitoxantrone and assayed for extracellular ATP release (left) kinetically over 24 hours using the RealTime-Glo™ Extracellular ATP Assay. Lumit™ HMGB1 Immunoassay reagents were added directly to the second plate of treated cells after 24 hours of treatment. Mitoxantrone produces a dose- and time-dependent release of extracellular ATP (left) and a dose-dependent release of HMGB1 (right) with potency agreement between the two measurements of damage-associated molecular patterns.

Detect Drug-Induced Immunogenic Cell Death in Various Cell Culture Models

Drug-induced immunogenic cell death detected with HMGB1 assay.

Human U2OS cells (left) and mouse EL4 cells (right) were treated with doxorubicin for 24 hours. After 24 hours, the Lumit™ HMGB1 Immunoassay was performed directly on cell culture samples to measure HMGB1 released from treated cells.

아래 링크를 클릭하시면 제품에 대한 자세한 정보를 확인하실 수 있습니다.